Seminars in Pediatric Surgery
Volume 15, Issue 4 , Pages 242-250 , November 2006

Extracorporeal life support

References 

  1. Bartlett R. Extracorporeal life support for cardiopulmonary failure. Curr Probl Surg. 1990;27:621
  2. Kurusz M, Zwischenberger JB. Logistics of an ECMO programme. Perfusion. 1991;6(3):175–181
  3. Hirschl RM, Bartlett RH. Extracorporeal membrane oxygenation support in cardiorespiratory failure. Adv Surg. 1987;21:189
  4. Hattler BG, Lund LW, Golob J, Russian H, Lann MF, Merrill TL, et al. A respiratory gas exchange catheter: in vitro and in vivo tests in large animals. J Thorac Cardiovasc Surg. 2002;124(3):520–530
  5. Heiss KF, Pettit B, Hirschl RB, Cilley RE, Chapman R, Bartlett RH. Renal insufficiency and volume overload in neonatal ECMO managed by continuous ultrafiltration. ASAIO Trans. 1987;33(3):557–560
  6. Stange J, Mitzner SR, Risler T, Erley CM, Lauchart W, Goehl H, et al. Molecular adsorbent recycling system (MARS): clinical results of a new membrane-based blood purification system for bioartificial liver support. Artif Organs. 1999;23(4):319–330
  7. ELSO: The registry of the extracorporeal life support organization (updated annually). elso@med.umich.edu, Ann Arbor, MI.
  8. Bartlett RH, Gazzaniga AB, Huxtable RF, et al. Extracorporeal circulation (ECMO) in neonatal respiratory failure. J Thorac Cardiovasc Surg. 1977;74:826
  9. Bartlett RH, Gazzaniga AB, Huxtable RH, et al. Extracorporeal membrane oxygenation (ECMO) in newborn respiratory failure: technical considerations. Trans Am Soc Artif Intern Organs. 1979;25:473
  10. Bartlett RH, Andrews AF, Toomasian JM, et al. Extracorporeal membrane oxygenation for newborn respiratory failure: forty-five cases. Surgery. 1982;92:425
  11. Bartlett RH, Roloff DW, Cornell RG, et al. Extracorporeal circulation in neonatal respiratory failure: a prospective randomized study. Pediatrics. 1985;76:479
  12. O’Rourke PP, Crone RK, Vacanti JP, et al. Extracorporeal membrane oxygenation and conventional medical therapy in neonates with persistent pulmonary hypertension of the newborn: a prospective randomized study. Pediatrics. 1989;84:957
  13. Firmin R. United Kingdom Neonatal ECMO Study. Presented at the 7th International ELSO Conference, September 30, 1995, Dearborn, MI.
  14. Petrou S, Bischof M, Bennett C, et al. Cost-effectiveness of neonatal extracorporeal membrane oxygenation based on 7-year results from the United Kingdom Collaborative ECMO Trial. Pediatrics. 2006;117(5):1640–1649
  15. Timmons OD, Dean JM, Vernon DD. Mortality rates and prognostic variables in children with ARDS. J Pediatr. 1991;119:896
  16. Green TP, Timmons OD, Fackler JC, et al. The impact of extracorporeal membrane oxygenation on survival in pediatric patients with acute respiratory failure. Presented at Society of Critical Care Medicine 1994.
  17. Stolar CJ, Snedecor SM, Bartlett RH. Extracorporeal membrane oxygenation and neonatal respiratory failure: experience from the extracorporeal life support organization. J Pediatr Surg. 1991;26:563
  18. Bartlett RH, Gazzaniga AB, Toomasiam J, et al. Extracorporeal membrane oxygenation (ECMO) in neonatal respiratory failure, 100 cases. Ann Surg 204:236, 1986. membrane oxygenation. J Pediatrics. 1988;1131(pt 1):110–113Jul
  19. Ortega M, Ramos AD, Platzker AC, et al. Early prediction of ultimate outcome in newborn infants with severe respiratory failure. J Pediatr. 1988;113:744
  20. Rivera RA, Butt W, Shann F. Predictors of mortality in children with respiratory failure: possible indications for ECMO. Anesth Intensive Care. 1990;18:385
  21. Cilley RE, Zwischenberger JB, Andrews AF, et al. Intracranial hemorrhage during extracorporeal membrane oxygenation in neonates. Pediatrics. 1986;78:699
  22. Hirschl RB, Schumacher RE, Snedecor SN, et al. The efficacy of extracorporeal life support in premature and low birth weight newborns. J Pediatr Surg. 1993;28:1336
  23. Meinhardt JP, Annich GM, Miskulin J, et al. Thrombogenicity is not reduced when heparin and phospholipids bonded circuits are used in a rabbit model of extracorporeal circulation. ASAIO J. 2003;49:395–400
  24. Annich GM, Meinhardt JP, Bartlett RH, et al. Reduced platelet activation and thrombosi in extracorporeal circuits coated with nitric oxide release polymers. Crit Care Med. 2000;28(4):915–920
  25. Frost MC, Reynolds MM, Meyerhoff ME. Polymers incorporating nitric oxide releasing/generating substances for improved biocompatibility of blood-contacting medical devices. Biomaterials. 2005;26:1685–1693
  26. Zhang H, Annich GM, Miskulin J, Osterholzer K, Merz SI, Bartlett RH, et al. Nitric oxide releasing silicone rubbers with improved blood compatibility: preparation, characterization, and in vivo evaluation. J Am Chem Soc. 2003;125(17):5015–5024
  27. Ivascu FA, Somand DM, Bartlett RH, et al. Development of an artificial placenta: CO2 elimination and hemodynamics as a function of arteriovenous blood flow. J Pediatr Surg. 2005;40:1034–1037
  28. Haft JW, Bull JL, Rose R, et al. Design of an artificial lung compliance chamber for pulmonary replacement. ASAIO J. 2003;49:35–40
  29. Pranikoff T, Hirschl RH, Custer JR, et al. Survival is inversely proportional to the duration of mechanical ventilation prior to pediatric extracorporeal life support. Presented at the American Academy of Pediatrics Section on Surgery, October 22, 1994, Dallas, TX.
  30. Lewis DA, Gauger P, Delosh TN, Dechert RE, Hirschl RB. The effect of pre-ECLS ventilation time on survival and respiratory morbidity in the neonatal population. J Pediatr Surg. 1996;31(8):1110–1114
  31. Toomasian JM, Schreiner RJ, Meyer DE, et al. A polymethylpentene fiber gas exchanger for long-term extracorporeal life support. ASAIO J. 2005;51:390–397
  32. von Allmen D, Ryckman FC. Cardiac arrest in the ECMO candidate. J Pediatr Surg. 1991;26:143
  33. Dickey LA, Cheu HW. Neonates requiring cardiopulmonary resuscitation before extracorporeal membrane oxygenation: prognostic factors for survival and neurologic outcome. Presented at the 9th Annual Children’s National Medical Center ECMO Symposium, February 28, 1993, Keystone, CO.
  34. del Nido PJ, Dalton HJ, Thompson AE, et al. Extracorporeal membrane oxygenator rescue in children during cardiac arrest after cardiac surgery. Circulation. 1992;86:II300
  35. Perchinsky MJ, Long WB, Hill JG, et al. Extracorporeal cardiopulmonary life support with heparin-bonded circuitry in the resuscitation of massively injured trauma patients. Am J Surg. 1995;169(5):488–491
  36. Faulkner SC, Chipman CW, Moss MM, et al. Extracorporeal life support of neonates with congenital cardiac defects: techniques used during cardiac catheterization and surgery. J Extra Corpor Technol. 1994;26(1):28–33
  37. Peek GJ, Firmin RK. The inflammatory and coagulative response to prolonged extraco rporeal membrane oxygenation. ASAIO J. 1999;45(4):250–263
  38. Heiss K, Manning P, Oldham KT, et al. Reversal of mortality for congenital diaphragmatic hernia with ECMO. Ann Surg. 1989;209:225
  39. Newman KD, Anderson KD, Van Meurs K, et al. Extracorporeal membrane oxygenation and congenital diaphragmatic hernia: should any infant be excluded?. J Pediatr Surg. 1990;25:1048
  40. Steimle CN, Meric F, Hirschl RB, et al. Effect of extracorporeal life support on survival when applied to all patients with congenital diaphragmatic hernia. J Pediatr Surg. 1994;29:997
  41. Stolar C, Dillon P, Reyes C. Selective use of extracorporeal membrane oxygenation in the management of congenital diaphragmatic hernia. J Pediatr Surg. 1988;23:207
  42. Secker-Walker JS, Edmonds JF, Spratt EH, et al. The source of coronary perfusion during partial bypass for extracorporeal membrane oxygenation (ECMO). Ann Thorac Surg. 1976;21:138
  43. Cornish JD, Heiss KF, Clark RH, et al. Efficacy of venovenous extracorporeal membrane oxygenation for neonates with respiratory and circulatory compromise. J Pediatr. 1993;122:105
  44. Anderson H, Snedecor SM, Otsu T, et al. Multicenter comparison of conventional venoarterial access versus venovenous double-lumen catheter access in newborn infants undergoing extracorporeal membrane oxygenation. J Pediatr Surg. 1983;28:530
  45. Gauger PG, Hirschl RB, Delosh TN, et al. A matched pairs analysis of venoarterial and venovenous extracorporeal life support in neonatal respiratory failure. ASAIO J. 1995;41:M573
  46. Wang DW, Lick SD, Campbell KM, et al. Development of ambulatory arterio-venous carbon dioxide removal (AVCO2R): the downsized gas exchanger prototype for ambulation removes enough CO2 with low blood resistance. ASAIO J. 2005;51:385–389
  47. Zhou X, Loran DB, Wang D, et al. Seventy-two hour gas exchange performance and hemodynamic properties of NOVALUNG iLA as a gas exchanger for arteriovenous carbon dioxide removal. Perfusion. 2005;20:303–308
  48. Mortenson JD, Berry G. Conceptual and design features of a practical, clinically effective intravenous mechanical blood oxygen/carbon dioxide exchange device (IVOX). Int J Artif Organs. 1989;12(6):384–389
  49. Walsh-Sukys MC, Bauer RE, Cornell DJ, et al. Severe respiratory failure in neonates: mortality and morbidity rates and neurodevelopmental outcomes. J Pediatrics. 1994;125:104
  50. Zwischenberger JB, Nguyen TT, Upp J, et al. Complications of neonatal extracorporeal membrane oxygenation: collective experience from the extracorporeal life support organization. J Thorac Cardiovasc Surg. 1994;107:838
  51. Upp J, Bush PE, Zwischenberger JB. Complications of neonatal extracorporeal membrane oxygenation. Perfusion. 1994;9:241
  52. Jarjour IT, Ahdab-Barmada M. Cerebrovascular lesions in infants and children dying after extracorporeal membrane oxygenation. Pediatr Neurol. 1994;10:13
  53. Bowerman RA, Zwischenberger JB, Andrews AF, et al. Cranial sonography of the infant treated with extracorporeal membrane oxygenation. AJR Am J Roentgenol. 1985;145:161
  54. Bulas DI, Taylor GA, Fitz CR, et al. Posterior fossa intracranial hemorrhage in infants treated with extracorporeal membrane oxygenation: sonographic findings. AJR Am J Roentgenol. 1991;156:571
  55. Anderson H, Cilley RE, Zwischenberger JB, et al. Thrombocytopenia in neonates after extracorporeal membrane oxygenation. ASAIO Trans. 1986;32:534
  56. Wilson JM, Bower LK, Fackler JC, et al. Aminocaproic acid decreases the incidence of intracranial hemorrhage and other hemorrhagic complications of ECMO. J Pediatr Surg. 1993;28:536
  57. Short BL, Walker LK, Traystman RJ. Impaired cerebral autoregulation in the newborn lamb during recovery from severe, prolonged hypoxia, combined with carotid artery and jugular vein ligation. Crit Care Med. 1994;22:1262
  58. Walker LK, Short BL, Gleason CA, et al. Cerebrovascular response to carbon dioxide in lambs receiving extracorporeal membrane oxygenation. Crit Care Med. 1994;22:291
  59. Zhou Z, Meyerhoff ME. Preparation and characterization of polymeric coatings with combined nitric oxide release and immobilized active heparin. Biomaterials. 2005;26:6506–6517
  60. Lick SC, Zwischenberger JB. Artificial lung: bench toward bedside. ASAIO J. 2004;50(1):2–5
  61. Griffith GW, Toomasian JM, Schreiner RJ, et al. Hematological changes during short-term ideal flow extracorporeal life support. Perfusion. 2004;19:359–363
  62. Campbell LR, Bunyapen C, Gangarosa ME, et al. Significance of seizures associated with extracorporeal membrane oxygenation. J Pediatr. 1991;119:789
  63. Streletz LJ, Bej MD, Graziani LJ, et al. Utility of serial EEGs in neonates during extracorporeal membrane oxygenation. Pediatr Neurol. 1992;8:190
  64. Liem KD, Hopman JC, Oeseburg B, et al. Cerebral oxygenation and hemodynamics during induction of extracorporeal membrane oxygenation as investigated by near infrared spectrophotometry. Pediatrics. 1995;95:555
  65. Toomasian JM, Snedecor SM, Cornell RG, et al. National experience with extracorporeal membrane oxygenation for newborn respiratory failure (Data from 715 cases). ASAIO Trans. 1988;34:140
  66. Lott IT, McPherson D, et al. Long term neurophysiologic outcome after neonatal extracorporeal membrane oxygenation. J Pediatr. 1990;116(3):343–349
  67. Schumacher RE, Palmer TW, Roloff DW, et al. Follow-up of infants treated with extracorporeal membrane oxygenation for newborn respiratory failure. Pediatrics. 1991;87:451
  68. Towne BH, Lott LT, Hicks DA, et al. Long-term follow-up of infants and children treated with extracorporeal membrane oxygenation (ECMO): a preliminary report. J Pediatr Surg. 1985;20(4):410–414
  69. Zapol WM, Kolobow T, Pierce Jevurek GG, Bowman RL. Artificial placenta: two days of total extrauterine support of the isolated premature lamb fetus. Science. 1969;166(905):617–618
  70. Mortensen JD. An intravenacaval blood gas exchange (IVCBGE) device (A preliminary report). ASAIO Trans. 1987;33(3):570–573

PII: S1055-8586(06)00051-5

doi: 10.1053/j.sempedsurg.2006.07.003

Seminars in Pediatric Surgery
Volume 15, Issue 4 , Pages 242-250 , November 2006